DTH: 5-1/8" in [130 mm] OD bit and 3-1/2" in [89 mm]
OD drill pipe to 800' ft. [243 m]
Reverse Circulation: 4.5" RC drill pipe to 400' ft. [122 m] Hollow Stem Auger: 3-1/4" in [83 mm] ID to 175' ft [53 m] Continuous Flight Auger: 6" in [152 mm]
OD to 300' ft [91 m]
Rotary Drilling: NW drill rod to 1,500' ft [457 m] Diamond Core Drilling: N Wireline to 1,600' ft [487 m]
Note: Above drilling capacities may vary according to subsurface conditions, hoist capacity and drilling medium gpm and psi.
HOIST
MAIN
Single Line Capacity: 8,500 lbs [3,855.5 kg]
Line speed: 0–75 fpm [22.9 m/min]
Cable diameter: 1/2" in (.500) [12.7 mm]
Cable length: 100' ft [30.5 m]
AUXILIARY
Single Line Capacity: 4,500 lbs [2,041 kg]
Line speed: 0–135 fpm [41.2 m/min]
Cable diameter: 5/16" in (.325) [8.3 mm]
Cable length: 100' ft [30.5 m]
WIRELINE
Single Line Capacity: 1,200 lbs [544.3 kg]
Line speed: 0–500' ft/min [152.4 m/min]
Cable diameter: 3/16" in (.185) [4.7 mm]
Cable length: 400' ft [121.9 m]
Winch capacity: 3,500' ft [1,067 m]
SAFE-T DRIVER
Single Line Capacity: 900 lbs [408.2 kg]
Line speed: variable up, freefall down
Cable diameter: 1/4" in (.250) [6.4 mm]
Cable length: 300' ft [91.4 m]
SPT AUTOMATIC HAMMER
ASTM D-1586 standards, standard duty and heavy duty 140 lb [63.5 kg], 170 lb [77.1 kg], 300 lb [136.1 kg],